About Jinwei Solar Cable Juncation Box PV connector PV Accessories PV inverter Contact Us
UL PV Wire TUV PV Cable Dual Certification PV Cable UL USE-2 Wire XLPE Cable






Jinwei Photovoltaic Power Wires
UL Approved Number : E333239 
 


美規UL Specification of Photovoltaic Power Wires

Application
Single or Double insulated, moisture curable cross-linked cables for Photovoltaic power applications.

Construction
Conductor: Tinned copper strands, according to VDE 0295 / IEC 60228, class 5 / UL854 class B
Insulation: Polyolefin Copolymer moisture curable cross-linked
Outer sheath: Polyolefin Copolymer moisture curable cross-linked
Sheath color: Black, Red, Blue, All Color

Technical specification
voltage rating: 600 V / 1000 V
Test voltage: 3000 V, 60 Hz, 1 min.
Temperature rating:  90 °C dry or wet
                             194 °F dry or wet
Ambient temperature: > 25 years (TÜV)
                                 – 40 °C up to + 90 °C
                                 – 40 °F up to + 194 °F
Max. short circuit temperature: 250 °C, +482 °F
Bending radius:≥ 5 × outer diameter



Marking
JINWEI PVS***-* Solar Photovoltaic Wire *** mm2 (11AWG ) 90℃ Dry and Wet 600V Sun Res. -40℃ E333239 (UL)

Standards / Material properties
Fire performance: IEC 60332-1; UL 1581 1060 / VW1
Approvals: UL 4703 PV wire
Application standards: NEC 2008 / UL 4703 PV wire,

Features & Benefits
Robust design.
Moisture curable cross-linked.
Resistance against UV, water, ozone, fluids, oil, salt and general weathering.
Flame retardant.
Colors: Red, Blue, Black.
RoHS compliant.
UL certified.
Compatible to all popular connectors

美規UL Specification of Photovoltaic Power Wires
USA Standard 600V Single Layer
Item   PVS-620 PVS-625 PVS-633 PVS-640 PVS-653 PVS-660
UL AWG 14 13 12 11 10 9
Section Size mm2 2.08 2.50 3.31 4.00 5.32 6.00
Structure   41/0.254 TC 49/0.254 TC 65/0.254 TC 56/0.30TC 75/0.30 TC 84/0.30 TC
Conductor  ID mm 1.88 2.05 2.40 2.60 3.00 3.18
XLPE Thickness mm 1.6 1.63 1.60 1.60 1.60 1.61
Jacket  OD mm 5.1 5.3 5.6 5.8 6.2 6.4
Weight kg / 100M 4.19 4.71 5.63 6.37 7.86 8.59
Allow Current A / mm2 27 29.6 35.9 39.4 47.5 49.7
Conductor Resistance Ω/km 9.07 7.35 5.71 4.60 3.59 3.06
USA Standard 600V Double Layer
Item   PVD-620 PVD-625 PVD-633 PVD-640 PVD-653 PVD-660
UL AWG 14 13 12 11 10 9
Section Size mm2 2.08 2.50 3.31 4.00 5.32 6.00
Structure   41/0.254 TC 49/0.255 TC 65/0.254 TC 56/0.30 TC 75/0.30 TC 84/0.30 TC
Conductor  ID mm 1.88 2.05 2.40 2.60 3.00 3.18
XLPE Thickness mm 1.20 1.20 1.20 1.20 1.20 1.20
Insulation ID mm 4.28 4.45 4.80 5.00 5.40 5.58
XLPE Thickness mm 0.80 0.83 0.80 0.80 0.80 0.81
Jacket  OD mm 5.9 6.1 6.4 6.6 7.0 7.2
Weight kg / 100M 5.09 5.64 6.61 7.38 8.94 9.70
Allow Current A / mm2 28.7 31.2 36.7 41.2 49.6 51.8
Conductor Resistance Ω/km 9.07 7.35 5.71 4.60 3.59 3.06
USA Standard 1000V Single Layer
Item   PVS-1020 PVS-1025 PVS-1033 PVS-1040 PVS-1053 PVS-1060
UL AWG 14 13 12 11 10 9
Section Size mm2 2.08 2.50 3.31 4.00 5.32 6.00
Structure   41/0.254 TC 49/0.255 TC 65/0.254 TC 56/0.30TC 75/0.30 TC 84/0.30 TC
Conductor  ID mm 1.88 2.05 2.40 2.60 2.98 3.18
 XLPE Thickness mm 2.01 2.03 2.00 2.00 2.01 2.01
Jacket OD mm 5.9 6.1 6.4 6.6 7.0 7.2
Weight kg / 100M 5.09 5.64 6.61 7.38 8.94 9.70
Allow Current A / mm2 28.7 31.2 36.7 41.2 49.6 51.8
Conductor Resistance Ω/km 9.07 7.35 5.71 4.60 3.59 3.06
USA Standard 1000V Double Layer
Item   PVD-1020 PVD-1025 PVD-1033 PVD-1040 PVD-1053 PVD-1060
UL AWG 14 13 12 11 10 9
Section Size mm2 2.08 2.50 3.31 4.00 5.32 6.00
Structure   41/0.254 TC 49/0.255 TC 65/0.254 TC 56/0.30 TC 75/0.30 TC 84/0.30 TC
Conductor  ID mm 1.88 2.05 2.40 2.60 3.00 3.18
XLPE Thickness mm 1.61 1.63 1.60 1.60 1.60 1.61
Insulation ID mm 5.10 5.30 5.60 5.80 6.20 6.40
XLPE Thickness mm 0.80 0.80 0.80 0.80 0.80 0.80
Jacket  OD mm 6.7 6.9 7.2 7.4 7.8 8.0
Weight kg / 100M 6.12 6.71 7.72 8.53 10.10 10.90
Allow Current A / mm2 30 32.5 39.2 42.8 51.4 53.6
Conductor Resistance Ω/km 9.07 7.35 5.71 4.60 3.59 3.06











歐規TUV Specification of Photovoltaic Power Cables


Jinwei Photovoltaic Power Cable
TUV Approved Number : R50210847
 

Application
Double insulated, moisture curable cross-linked cables for Photovoltaic power applications.

Construction
Conductor: Tinned copper strands, according to VDE 0295 / IEC 60228, class 5 / UL854 class B
Insulation: Polyolefin Copolymer moisture curable cross-linked
Outer sheath: Polyolefin Copolymer moisture curable cross-linked
Sheath color: Black, Red, Blue, All Color

Technical specification
voltage rating: U0/U 0.6/1KV
Test voltage: 3000 V, 60 Hz, 1 min.
Temperature rating:  90 °C dry or wet
                             194 °F dry or wet
Ambient temperature: > 25 years (TÜV)
                                 – 40 °C up to + 90 °C
                                 – 40 °F up to + 194 °F
Max. short circuit temperature: 250 °C, +482 °F
Bending radius: ≥ 4 × outer diameter


Marking
TÜV JINWEI PVD***UT PV1-F 1X***mm2 20##

Standards / Material properties
Approvals: TUV
Application standards: 2Pfg 1169 / 08.2007

Features & Benefits
Robust design.
Moisture curable cross-linked.
Resistance against UV, water, ozone, fluids, oil, salt and general weathering.
Flame retardant.
Three colors: Red, Blue and Black.
RoHS compliant.
TUV certified.
Compatible to all popular connectors

歐規TUV Specification of Photovoltaic Power Cables

European Standard TUV Double Layer U0/U 0.6/1KV

Item

  PV1-F

PVD-625T

PVD-640T

PVD-660T

TUV

mm2

2.50

4.00

6.00

Section Size

AWG

13

11

9 

Structure

 

50/0.254 TC

80/0.254TC

85/0.30 TC

Conductor  ID

mm

2.1

2.6

3.2

Thickness

mm

0.70

0.70

0.80

XLPE Insulation ID

mm

3.5

4.0

4.8

Thickness

mm

0.90

0.95

1.05

XLPE Jacket OD

mm

5.3

5.9

6.9

OD Tolerance

mm

±0.2

±0.2

±0.2

Bending Radius

mm

>  4 x CABLE OUTER DIAMETER

Weight

kg / 100M

5.39

7.51

10.36

Allow Current

A / mm2

31.2

41.2

51.8

Conductor Resistance R20  max

Ω/km

8.21

5.09

3.39


日規PSE Specification of Photovoltaic Power Cables
(The PSE Certification is in proceeding.)

Japan PSE Standard Double Layer 600V

Item

 

PVD-620P

PVD-635P

PVD-655P

UL

mm2

2.00

3.50

5.50

Section Size

AWG

14

12+

10+

Structure

 

40/0.254 TC

68/0.254 TC

78/0.30 TC

Conductor  ID

mm

1.83

2.42

3.05

Thickness

mm

0.77

0.79

0.90

XLPE Insulation ID

mm

3.4

4.0

5.0

Thickness

mm

1.5

1.5

1.5

XLPE Jacket OD

mm

6.4

7.0

8.0

OD Tolerance

mm

±0.2

±0.2

±0.2

Bending Radius

mm

>  4 x CABLE OUTER DIAMETER

Weight

kg / 100M

6.5

8.5

11.9

Allow Current

A / mm2

33.6

50.4

66.8

Conductor Resistance R20  max

Ω/km

9.25

5.36

3.35












Dual Certification TUV & UL Specification of Photovoltaic Cables

Jinwei Dual Certification PV Power Cable
TÜV Approved Number : R50210847
UL Approved Number: E333239
 

Application
Double insulated, moisture curable cross-linked cables for Photovoltaic power applications.

Construction
Conductor: Tinned copper strands, according to VDE 0295 / IEC 60228, class 5 / UL854 class B
Insulation: Polyolefin Copolymer moisture curable cross-linked
Outer sheath: Polyolefin Copolymer moisture curable cross-linked
Sheath color: Black, Red, Blue, All Color

Technical specification
voltage rating: U0/U 0.6/1KV
Test voltage: 3000 V, 60 Hz, 1 min.
Temperature rating:  90 °C dry or wet
                             194 °F dry or wet
Ambient temperature: > 25 years (TÜV)
                                 – 40 °C up to + 90 °C
                                 – 40 °F up to + 194 °F
Max. short circuit temperature: 250 °C, +482 °F
Bending radius: ≥ 4 × outer diameter


Marking


Standards / Material properties
Fire performance: IEC 60332-1; UL 1581 1060 / VW1
Approvals: TÜV 2Pfg 1169 / 08.2007
Approvals: UL 4703 PV wire
Application standards: NEC 2008 / UL 4703 PV wire,
Application standards: 2Pfg 1169 / 08.2007

Features & Benefits
Robust design.
Moisture curable cross-linked.
Resistance against UV, water, ozone, fluids, oil, salt and general weathering.
Flame retardant.
Three colors: Red, Blue and Black.
RoHS compliant.
TÜV & UL Dual Certification.
Compatible to all popular connectors

Dual Certification TUV & UL Specification of Photovoltaic Cables

Double Layer U0/U 0.6/1KV

Item

 

PVD-625UT

PVD-640UT

PVD-660UT

UL

mm2

2.50

4.00

6.00

Section Size

AWG

13

11

9

Structure

 

50/0.254 TC

80/0.254 TC

84/0.30 TC

Conductor  ID

mm

2.1

2.6

3.2

Thickness

mm

1.20

1.20

1.20

XLPE Insulation ID

mm

4.5

5.0

5.6

Thickness

mm

1.0

1.0

1.0

XLPE Jacket OD

mm

6.5

7.0

7.6

OD Tolerance

mm

±0.2

±0.2

±0.2

Bending Radius

mm

>  4 x CABLE OUTER DIAMETER

Weight

kg / 100M

7.00

8.90

11.50

Allow Current

A / mm2

31.2

41.2

51.8

Conductor Resistance R20  max

Ω/km

8.21

5.09

3.39













Jinwei USE-2 PV Wires


UL Approved Number : E342639 
 

 



Application
Single insulated, moisture curable cross-linked USE-2 cable is UL 854 Service- Entrance Cable for Grounded PV system applications .

Construction
Conductor: Tinned copper strands, according to VDE 0295 / IEC 60228, class 5 / UL854 class B Insulation: Polyolefin Copolymer moisture curable cross-linked Sheath color: Black, Red, Blue, All Color

Technical specification
Voltage rating: U0/U: 600 V / 1000 V
Test voltage: 3000 V, 60 Hz, 1 min.
Temperature rating: 90 °C dry or wet / 194 °F dry or wet
Ambient temperature: > – 25 °C up to + 90 °C / – 104 °F up to + 194 °F
Bending radius: ≥ 5 × outer diameter


Standards / Material properties
Fire performance: IEC 60332-1; UL 1581 1060
Approvals: UL 854
Application standards: NEC 2008 / UL 1581 wire,

Features & Benefits
Robust design.
Moisture curable cross-linked.
Sunlight resistant, water, ozone, fluids, oil, salt and general weathering.
Flame retardant.
RoHS compliant.
Compatible to all popular connectors

USA Standard 600V Single Layer
Item   USE-2-620 USE-2--625 USE-2--633 USE-2--640 USE-2--653 USE-2--660
UL AWG 14 13 12 11 10 9
Section Size mm2 2.08 2.50 3.30 4.00 5.30 6.00
Structure   41/0.254 TC 49/0.254 TC 65/0.254 TC 56/0.30TC 75/0.30 TC 84/0.30 TC
Conductor  ID mm 1.88 2.05 2.30 2.60 3.00 3.18
XLPE Thickness mm 1.15 1.15 1.15 1.15 1.15 1.15
Jacket OD mm 4.2 4.3 4.6 4.9 5.3 5.5
Weight kg / 100M 3.2 3.6 4.5 5.2 6.6 7.3
Allow Current A / mm2 27 29.6 35.9 39.4 47.5 49.7
Conductor Resistance Ω/km 9.07 7.35 5.71 4.6 3.59 3.06











Jinwei XLPE Cables


 

 



Application
Single or Double insulated, moisture curable cross-linked XLPE cable is similar to USE-2 Service Entrance Cable for Grounded PV system applications and Conduit layout required. .

Construction
Conductor: Tinned copper strands, according to VDE 0295 / IEC 60228, class 5 / UL854 class B Insulation: Polyolefin Copolymer moisture curable cross-linked Jacket color: Black, Red, Blue, All Color

Technical specification
Voltage rating: U0/U: 600 V / 1000 V
Test voltage: 3000 V, 60 Hz, 1 min.
Temperature rating: 90 °C dry or wet / 194 °F dry or wet
Ambient temperature: > – 25 °C up to + 90 °C / – 104 °F up to + 194 °F
Bending radius: ≥ 5 × outer diameter

Standards / Material properties
According to UL 854
Application standards: Similar to NEC 2008 / UL 1581 wire,

Features & Benefits
Robust design.
Moisture curable cross-linked.
General weather resistant, water, ozone, fluids, oil, and salt.
RoHS compliant.
Compatible to all popular connectors

USA Standard 600V Single Layer
Item   XLPE-S620 XLPE-S625 XLPE-S633 XLPE-S640 XLPE-S653 XLPE-S660
UL AWG 14 13 12 11 10 9
Section Size mm2 2.08 2.50 3.30 4.00 5.30 6.00
Structure   41/0.254 TC 49/0.254 TC 65/0.254 TC 56/0.30TC 75/0.30 TC 84/0.30 TC
Conductor  ID mm 1.88 2.05 2.30 2.60 3.00 3.18
XLPE Thickness mm 1.15 1.15 1.15 1.15 1.15 1.15
Jacket OD mm 4.2 4.3 4.6 4.9 5.3 5.5
Weight kg / 100M 3.2 3.6 4.5 5.2 6.6 7.3
Allow Current A / mm2 27 29.6 35.9 39.4 47.5 49.7
Conductor Resistance Ω/km 9.07 7.35 5.71 4.6 3.59 3.06
 
   

Jinwei Wire & Cable Co.
No.311, Liouchiau E. Rd., Pusin , Changhua , Taiwan (51344)
Tel: +886-(0)4-8298657
Fax: +886-(0)4-8298649

Email: inquiry@jinweicable.com